LiveActive security incident?Get immediate response
CVE Record

CVE-2015-3965: Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated...

Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated operations" by leveraging "elevated privileges" for an unspecified call to an incorrectly exposed function.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysisunknown

Security readout for executives and security teams

Plain-English summary

This CVE affects Hospira Symbiq Infusion System 3.13 and earlier. A remote authenticated user with elevated privileges could trigger unspecified "unanticipated operations" through an incorrectly exposed function. The public record does not explain the clinical effect, severity, or fix, so organizations should first confirm whether any Symbiq pumps remain deployed or reachable.

Executive priority

Treat this as a healthcare technology exposure requiring prompt asset confirmation. Business urgency depends on whether affected infusion systems remain deployed and reachable; the supplied sources do not establish active exploitation or a quantified severity score.

Technical view

The issue is an incorrectly exposed function callable by remote authenticated users leveraging elevated privileges. The affected product is Hospira Symbiq Infusion System versions 3.13 and earlier. The CVE record does not provide CVSS, CWE, function details, impact boundaries, or patch information in the supplied bundle.

Likely exposure

Exposure is limited to environments that still operate Hospira Symbiq Infusion System 3.13 or earlier, especially where device management paths are network-reachable by authenticated users.

Exploitation context

The supplied sources do not show CISA KEV listing or active exploitation. The issue requires remote authentication and elevated privileges, but the records do not define the exact privilege level, access path, or operation triggered.

Researcher notes

The public bundle is sparse: no CVSS, CWE, patch details, function name, or clinical impact are provided. Analysis should stay anchored to authenticated privileged misuse of an exposed function on Symbiq 3.13 and earlier.

Mitigation direction

  • Inventory Hospira Symbiq Infusion Systems and record software versions.
  • Prioritize devices running version 3.13 or earlier for review.
  • Check Hospira, FDA, or CISA ICS-CERT guidance for approved remediation.
  • Restrict network access to device management interfaces where operationally feasible.
  • Review privileged accounts with access to infusion system management functions.

Validation and detection

  • Confirm whether any Symbiq Infusion Systems remain in production or storage.
  • Verify firmware or software versions against the affected range.
  • Review network segmentation around clinical device management networks.
  • Check logs or access records for unexpected privileged remote activity.
  • Document any compensating controls until vendor guidance is confirmed.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2015-3965 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
HospiraSymbiq Infusion System3.13 and earlierListed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.