Security readout for executives and security teams
This CVE concerns industrial HMI/SCADA software storing project-window passwords in cleartext. A person with local access to the workstation or project files could read the stored password. The issue is not described as remotely exploitable, but it can weaken controls around engineering projects and operator environments. Exposure is most likely on engineering workstations, HMI development systems, or shared project repositories running the listed affected versions. Systems without local user access or exposed project files have lower practical exposure. Treat this as a targeted operational technology hygiene issue, not an internet-scale emergency. Prioritize sites where shared workstations, contractors, or broad file access could expose engineering project passwords. Mitigation focus: Identify installations of the affected Schneider and Wonderware products.; Apply the vendor update or guidance referenced by Schneider and ICS-CERT.; Restrict local OS access to engineering workstations and project directories..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
Credential and access behavior lookup
The CVE wording references authentication or credential exposure, so valid-account and credential-access review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.
Open ATT&CK lookupCVE-2015-1009 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Unknown
- CVSS
- Not scored
- Known Exploited
- No
- Published
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS and timeline data
No CVSS vectors or timeline events were available in the normalized CVE source material.
Source materials
- CVE List V5 sourceCVE List V5
- https://ics-cert.us-cert.gov/advisories/ICSA-15-211-01CVE reference · x_refsource_MISC
- https://gcsresource.invensys.com/support/docs/_securitybulletins/Security_bulletin_LFSEC00000110.pdfCVE reference · x_refsource_MISC
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.