Security readout for executives and security teams
This issue affects the web login for Nordex Control 2 wind farm SCADA devices. A remote attacker could inject script or HTML through the username field. For executives, the concern is not just a website bug: the affected interface belongs to operational technology supporting wind farm control environments. Exposure is most likely where Nordex Control 2 Wind Farm Portal login interfaces for version 15 or earlier are reachable from untrusted networks. The bundle does not prove broad internet exposure or list exact deployment counts. Treat this as high priority for any affected wind farm control environment, especially if the portal is remotely accessible. Prioritize exposure reduction and vendor-guided remediation before routine IT web issues. Mitigation focus: Check current Nordex and CISA guidance for supported remediation details.; Identify and prioritize NC2 version 15 or earlier deployments.; Restrict Wind Farm Portal access to trusted management networks only..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-79: User-session and phishing behavior lookup
Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupCVE-2014-5408 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- High
- CVSS
- 7.5 (2.0)
- Known Exploited
- No
- Published
Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS vector scores
1 official scoreWe collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
AV:N/AC:L/Au:N/C:P/I:P/A:P106.4Primary CVE scoreVulnerability scoring details
Base CVSS 2.0 score
7.5HighVector: AV:N/AC:L/Au:N/C:P/I:P/A:P
Source materials
- CVE List V5 sourceCVE List V5
- https://www.cisa.gov/news-events/ics-advisories/icsa-14-303-01CVE reference
- https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-303-01.jsonCVE reference
- https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01CVE reference · x_refsource_MISC, x_transferred
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.