Security readout for executives and security teams
Advantech WebAccess before version 7.2 can expose stored credentials to a remote authenticated user. For organizations using this industrial control software, the main risk is credential disclosure that could enable wider system compromise if exposed accounts have meaningful privileges. Exposure is most likely in environments running Advantech WebAccess versions earlier than 7.2, especially where authenticated WebAccess access is reachable over enterprise, vendor, or remote-access networks. Treat as high-priority if Advantech WebAccess is present in operational technology environments. The issue is old but severe, and legacy ICS deployments often persist beyond vendor patch cycles. Mitigation focus: Identify all Advantech WebAccess installations and versions.; Upgrade systems before 7.2 to 7.2 or later per vendor guidance.; Restrict WebAccess administrative access to trusted networks and users..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-316: Exact CWE lookup
Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupCVE-2014-2366 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Critical
- CVSS
- 9 (2.0)
- Known Exploited
- No
- Published
Vector: AV:N/AC:L/Au:S/C:C/I:C/A:C
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS vector scores
1 official scoreWe collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
AV:N/AC:L/Au:S/C:C/I:C/A:C810Primary CVE scoreVulnerability scoring details
Base CVSS 2.0 score
9CriticalVector: AV:N/AC:L/Au:S/C:C/I:C/A:C
Source materials
- CVE List V5 sourceCVE List V5
- https://www.cisa.gov/news-events/ics-advisories/icsa-14-198-02CVE reference
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
Cleartext Storage of Sensitive Information in Memory
Cleartext Storage of Sensitive Information in Memory represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.
