Security readout for executives and security teams
This vulnerability affects an old National Instruments ActiveX component used by NI engineering software and ABB DataManager. If exposed through a vulnerable application or browser context, an attacker could cause arbitrary files to be created and executed. That makes legacy engineering and industrial workstations the main business concern. Likely exposure is legacy Windows systems with NI LabWindows/CVI 2012 SP1 or earlier, NI LabVIEW 2012 SP1 or earlier, ABB DataManager 1 through 6.3.6, or other products bundling cwui.ocx. Treat this as a legacy technology risk with potentially high impact. Prioritize discovery and vendor-guided remediation on engineering, lab, and industrial support workstations, especially where old ActiveX components remain reachable from untrusted content. Mitigation focus: Check NI and ABB advisories for supported fixes or upgrade paths.; Inventory systems for affected NI, ABB, and bundled cwui.ocx deployments.; Remove unsupported vulnerable software where it is no longer operationally required..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
File access behavior lookup
The CVE wording references file access or upload behavior, so file telemetry and web shell review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.
Open ATT&CK lookupCVE-2013-5021 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Unknown
- CVSS
- Not scored
- Known Exploited
- No
- Published
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS and timeline data
No CVSS vectors or timeline events were available in the normalized CVE source material.
Source materials
- CVE List V5 sourceCVE List V5
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
