LiveActive security incident?Get immediate response
CVE Record

CVE-2007-6226: The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu...

The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

This CVE affects an older APC switched rack PDU model. The issue could let a remote attacker gain login access under a specific multi-client session condition. Because PDUs control rack power, unauthorized access can create operational disruption risk even though public sources do not show active exploitation. Exposure is likely limited to legacy APC AP7932 PDUs with the named rpdu and aos firmware, especially if management interfaces are reachable from untrusted networks. Asset inventory is essential because the CVE record’s affected-product metadata is incomplete. Prioritize if affected PDUs are still deployed in production racks or reachable beyond a controlled management network. The technical scope is narrow, but compromise of rack power infrastructure can affect availability and incident recovery. Mitigation focus: Check APC or Schneider Electric guidance for supported firmware or replacement options.; Remove PDU management interfaces from internet and untrusted network reachability.; Restrict administration to a management VLAN and approved source IPs..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2007-6226 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/an/an/aListed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.