LiveActive security incident?Get immediate response
MITRE ATT&CK® Reference

Detections

Detection strategies and analytics from ATT&CK where present.

3,218 records · validated library

Detections results

Results are validated against normalized ATT&CK source records when available; sample records are used only in development or empty-data environments.

AnalyticICS

AN2046: Analytic 2046

Real-time monitoring identifies iptables/nftables rule changes on Industrial Control System (ICS) Linux gateways that selectively block one ICS communication traffic type. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Linux
AnalyticICS

AN2047: Analytic 2047

Real-time monitoring identifies the full firmware modification chain: a device entering firmware-update mode, receiving a large data transfer on a firmware-capable protocol port from a source not in the approved engineering workstation list, rebooting, and reporting a post-reboot firmware hash that does not match the authorized inventory. This technique-level analytic synthesizes System Firmware (T1693.001) and Module Firmware (T1693.002). OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Embedded
AnalyticICS

AN2048: Analytic 2048

Real-time monitoring identifies successful authentication to Windows-hosted Industrial Control System (ICS) applications using credentials matching known default or hardcoded vendor passwords. OT operational-fidelity gate: Alert only when the account/device/session violates the approved identity + source host/jump path/zone policy and is corroborated by access to a protected OT asset, execution, configuration change, or another security-relevant follow-on event. Suppress approved shift activity, vendor support, break-glass use, commissioning, and documented remote-access windows.

Windows
AnalyticICS

AN2049: Analytic 2049

Configured Windows object-access monitoring identifies a write to a Siemens project file by a process that is not the Siemens Totally Integrated Automation (TIA) Portal or Step7 engineering software, or by the legitimate Siemens tool immediately after loading a project from an untrusted path. Directly documented as a Stuxnet mechanism. OT operational-fidelity gate: Alert only when execution violates an approved signer/hash/path/parent/process or tool allowlist, or originates from an unauthorized user/tool, and is tied to an OT asset or follow-on OT-relevant action. Suppress vendor-signed software, approved engineering utilities, diagnostics, patching, backup, and documented maintenance. Collection requirement: use Windows Security Event ID 4663 with Object Access auditing and SACLs on approved project repositories; Sysmon FileCreate events can corroborate writes/overwrites but do not report generic file-open/read activity.

Windows
AnalyticICS

AN2050: Analytic 2050

Real-time monitoring identifies execution of port scanning utilities (nmap, masscan) with arguments targeting Industrial Control System (ICS) protocol port ranges on an ICS Windows host. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Windows
AnalyticICS

AN2051: Analytic 2051

Real-time monitoring identifies new Internet Group Management Protocol (IGMP) joins or broadcast traffic spikes on Industrial Control System (ICS) Virtual Local Area Networks (VLANs) from a source not in the approved device inventory. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Network Devices
AnalyticICS

AN2052: Analytic 2052

Real-time monitoring identifies Internet Group Management Protocol (IGMP) membership reports for Industrial Control System (ICS) multicast groups from a source not in the approved device inventory. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Network Devices
AnalyticICS

AN2053: Analytic 2053

Real-time monitoring identifies a network infrastructure configuration change that results in a communication gap between previously-connected Industrial Control System (ICS) zones, from a source not in the approved network administration list. This technique-level analytic synthesizes Serial COM (T1695.001), Ethernet (T1695.002), and Wi-Fi (T1695.003). OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Network Devices
AnalyticICS

AN2054: Analytic 2054

Real-time monitoring identifies a Windows network-adapter disable or administrative interface-down event on an ICS gateway or protocol-converter host outside the approved network-maintenance window. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Windows
AnalyticICS

AN2055: Analytic 2055

Real-time monitoring identifies wireless controller management log entries showing Service Set Identifier (SSID) or Media Access Control (MAC) address filter configuration changes for the Industrial Control System (ICS) wireless network from an account not in the authorized wireless admins. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Windows
AnalyticICS

AN2056: Analytic 2056

Real-time monitoring identifies an Industrial Control System (ICS) protocol session reading back the complete program, configuration, and data block set from a field device in a single session from a source not in the approved engineering workstation list, distinguished from a partial Program Upload by the comprehensiveness of the read. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Embedded
AnalyticICS

AN2057: Analytic 2057

Real-time monitoring identifies an Industrial Control System (ICS) protocol session adding new program blocks or routines to an existing controller program without replacing existing logic, from a source not in the approved engineering workstation list, correlated against the device's program inventory showing a size increase without a corresponding planned update. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Embedded
AnalyticICS

AN2058: Analytic 2058

Real-time monitoring identifies an Industrial Control System (ICS) online-edit command sequence (incremental program modification while the device remains in RUN mode) from a source not in the approved engineering workstation list, outside a scheduled change-control window. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Embedded
AnalyticEnterprise

AN2059: Analytic 2059

Much of this takes place outside the visibility of the target organization, making detection difficult for defenders.

Detection efforts may be focused on related stages of the adversary lifecycle, such as during Initial Access.

PRE
AnalyticEnterprise

AN2060: Analytic 2060

Much of this takes place outside the visibility of the target organization, making detection difficult for defenders.

Detection efforts may be focused on related stages of the adversary lifecycle, such as during Initial Access.

PRE
AnalyticEnterprise

AN2061: Analytic 2061

Much of this takes place outside the visibility of the target organization, making detection difficult for defenders.

Detection efforts may be focused on related stages of the adversary lifecycle, such as during Initial Access.

PRE
AnalyticEnterprise

AN2062: Analytic 2062

Much of this takes place outside the visibility of the target organization, making detection difficult for defenders.

Detection efforts may be focused on related stages of the adversary lifecycle, such as during Initial Access.

PRE
AnalyticEnterprise

AN2063: Analytic 2063

Detection identifies execution of scripts or files that appear visually benign (low printable character ratio) but result in runtime decoding, dynamic evaluation, and subsequent process or network activity. Correlation links script execution with abnormal Unicode density and follow-on behavior such as child process creation or outbound connections.

Windows
AnalyticEnterprise

AN2064: Analytic 2064

Detection identifies execution of scripts containing high concentrations of invisible Unicode characters followed by decoding or interpretation behaviors (e.g., base64 decode, eval) and subsequent process or network activity. Emphasis is placed on mismatch between file entropy/structure and execution output.

Linux
AnalyticEnterprise

AN2065: Analytic 2065

Detection identifies execution of scripts or applications containing invisible Unicode payloads reconstructed at runtime, correlated with abnormal AppleScript, JavaScript for Automation, or shell execution and subsequent process or network behavior inconsistent with visible file content.

macOS
AnalyticICS

AN2066: Analytic 2066

Real-time monitoring identifies a field device loading a modified autorun image (boot read-only memory, bootloader firmware) detected by a discrepancy between the device's declared firmware hash and the authorized firmware inventory hash, with post-reboot device behavior diverging from expected (unexpected protocols active, unanticipated network connections). OT operational-fidelity gate: Alert only when execution violates an approved signer/hash/path/parent/process or tool allowlist, or originates from an unauthorized user/tool, and is tied to an OT asset or follow-on OT-relevant action. Suppress vendor-signed software, approved engineering utilities, diagnostics, patching, backup, and documented maintenance.

Embedded
AnalyticEnterprise

AN2068: Analytic 2068

No target-side behavioral analytic. A defender cannot reliably distinguish an adversary intentionally staging public content to manipulate future AI retrieval from ordinary publishing, SEO, inaccurate information, duplicated content, or legitimate coordinated publication using target-enterprise telemetry.

PRE
AnalyticEnterprise

AN2070: Analytic 2070

An analyst observes an authenticated AI interaction initiate resource access, tool invocation, API operation, or privileged activity outside $AuthorizedAIWorkflow$ or $AICapabilityScope$, without an authorized workflow transition permitting the operation.

SaaS
AnalyticEnterprise

AN2074: Analytic 2074

An analyst observes a supported security artifact/task enter an autonomous defensive-analysis workflow, the analysis begin successfully, and the same workflow subsequently record an explicit failure, refusal, termination, or abnormal terminal state inconsistent with $AuthorizedAnalysisStopConditions$.

SaaS
AnalyticEnterprise

AN2075: Analytic 2075

Detect creation of an application-specific password for a user account, correlated within ASPActivityWindow with authentication from a source, device, client, or location outside the account's established baseline, or followed by authentication using a legacy/non-MFA authentication path inconsistent with ApprovedASPUsage.

Identity Provider
Source and licensing

Source: MITRE ATT&CK®. © 2026 The MITRE Corporation. This work is reproduced and distributed with the permission of The MITRE Corporation. MITRE ATT&CK and ATT&CK are registered trademarks of The MITRE Corporation. Glexia is not affiliated with or endorsed by MITRE.