Adversaries may block access to serial COM to prevent instructions or configurations from reaching target devices. Serial Communication ports (COM) allow communication with control system devices. Devices can receive command and configuration messages over such serial COM. Devices also use serial COM to send command and reporting messages. Blocking device serial COM may also block command messages and block reporting messages.

A serial to Ethernet converter is often connected to a serial COM to facilitate communication between serial and Ethernet devices. One approach to blocking a serial COM would be to create and hold open a TCP session with the Ethernet side of the converter. A serial to Ethernet converter may have a few ports open to facilitate multiple communications. For example, if there are three serial COM available -- 1, 2 and 3 --, the converter might be listening on the corresponding ports 20001, 20002, and 20003. If a TCP/IP connection is opened with one of these ports and held open, then the port will be unavailable for use by another party. One way the adversary could achieve this would be to initiate a TCP session with the serial to Ethernet converter at 10.0.0.1 via Telnet on serial port 1 with the following command: telnet 10.0.0.1 20001.

ICST0805TechniqueObject v1.1 Modified
Historical object

This ATT&CK object is revoked or deprecated in the current MITRE ATT&CK release.

It remains available for historical context and inbound links. Use current ATT&CK relationships and replacement guidance before basing detection or reporting work on this page.

Glexia's Take

Analyst summary pending validation

Glexia publishes ATT&CK takes only after source-hash and schema validation. Until then, use the official MITRE definition below and the defensive relationship context on this page.

Official MITRE ATT&CK definition

Block Serial COM

Adversaries may block access to serial COM to prevent instructions or configurations from reaching target devices. Serial Communication ports (COM) allow communication with control system devices. Devices can receive command and configuration messages over such serial COM. Devices also use serial COM to send command and reporting messages. Blocking device serial COM may also block command messages and block reporting messages.

A serial to Ethernet converter is often connected to a serial COM to facilitate communication between serial and Ethernet devices. One approach to blocking a serial COM would be to create and hold open a TCP session with the Ethernet side of the converter. A serial to Ethernet converter may have a few ports open to facilitate multiple communications. For example, if there are three serial COM available -- 1, 2 and 3 --, the converter might be listening on the corresponding ports 20001, 20002, and 20003. If a TCP/IP connection is opened with one of these ports and held open, then the port will be unavailable for use by another party. One way the adversary could achieve this would be to initiate a TCP session with the serial to Ethernet converter at 10.0.0.1 via Telnet on serial port 1 with the following command: telnet 10.0.0.1 20001.

View the same entry on attack.mitre.org (MITRE-hosted reference; in-page links above use the Glexia ATT&CK library.)

Glexia analysis

How security teams should use this page

Treat this object as behavior context, not an attribution claim. Validate the related groups, software, data sources, and mitigations against official ATT&CK relationships and your own telemetry before making control-coverage decisions.

ATT&CK relationship table

Related techniques

This mirrors the MITRE pattern of making group, software, campaign, and technique relationships scannable. Relationship notes come from mirrored ATT&CK relationship text when available.

1 rows
Domain ID Name Relationship / procedure
ICS T1695.001 Serial COM Sub-technique This object revoked by Serial COM.
Relationship explorer

All related ATT&CK context

Change history

Object version and sync metadata

The fields below describe the current mirrored snapshot. When Glexia retains multiple ATT&CK source imports, you can open the table to compare the same object across releases (hashes and MITRE timestamps). For MITRE’s own release notes and roadmap, see ATT&CK resources — Updates .

ATT&CK release
19.1
Object version
1.1
Created
Modified
Raw hash
0076268830010c28...
Imported snapshots across ATT&CK releases (1)
Release Bundle imported Object version Modified Status Raw hash
19.1 1.1 Current bundle Revoked 007626883001…
Raw source

Mirrored ATT&CK source object

The raw object is retained through the mirrored ATT&CK source bundle and object hash. The raw endpoint returns the exact object from the mirrored bundle when available.

Source references

External references and citations

MITRE external references are preserved separately from Glexia analysis so citations remain traceable to their original source records.

  1. [1]
    mitre-attack T0805
    Open source URL
Source and licensing

Source: MITRE ATT&CK®. © 2026 The MITRE Corporation. This work is reproduced and distributed with the permission of The MITRE Corporation. MITRE ATT&CK and ATT&CK are registered trademarks of The MITRE Corporation. Glexia is not affiliated with or endorsed by MITRE.