{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-9395","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2026-05-24T06:18:55.457Z","datePublished":"2026-05-24T20:00:11.355Z","dateUpdated":"2026-05-26T13:20:38.881Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2026-05-24T20:00:11.355Z"},"title":"Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-522","lang":"en","description":"Insufficiently Protected Credentials"}]}],"affected":[{"vendor":"Besen","product":"BS20 EV Charging Station","versions":[{"version":"20260426","status":"affected"}],"cpes":["cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"],"modules":["BLE/UDP"]}],"descriptions":[{"lang":"en","value":"A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credentials. The attack needs to be initiated within the local network. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\""}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":5.1,"vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P","baseSeverity":"MEDIUM"}},{"cvssV3_1":{"version":"3.1","baseScore":3.5,"vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R","baseSeverity":"LOW"}},{"cvssV3_0":{"version":"3.0","baseScore":3.5,"vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R","baseSeverity":"LOW"}},{"cvssV2_0":{"version":"2.0","baseScore":2.7,"vectorString":"AV:A/AC:L/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2026-05-24T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2026-05-24T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2026-05-24T08:24:12.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"carfeii (VulDB User)","type":"reporter"},{"lang":"en","value":"VulDB CNA Team","type":"coordinator"}],"references":[{"url":"https://vuldb.com/vuln/365376","name":"VDB-365376 | Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials","tags":["vdb-entry"]},{"url":"https://vuldb.com/vuln/365376/cti","name":"VDB-365376 | CTI Indicators (IOB, IOC, TTP)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/submit/813572","name":"Submit #813572 | Besen EV Charging Station BS20 EV Charger Insufficiently Protected Credentials","tags":["third-party-advisory"]},{"url":"https://github.com/carfeii/besen#finding-2-cleartext-credential-exposure-via-ble-and-udp-in-besen-home-ev-charging-station","tags":["related"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-05-26T13:20:04.970912Z","id":"CVE-2026-9395","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-05-26T13:20:38.881Z"}}]}}